NV6 is the NVELOPE system for supporting a timber batten.

06. NV6

Next button to view next rainscreen cladding system.
Button to view cross section of rainscreen cladding system.
Button to view NV6 vertical bracket range with timber batten.

NV6 is the NVELOPE system
for supporting a timber batten / Hybrid.

Suitable for supporting vertical or horizontal timber or cement weatherboarding. Panels may then be attached to support other materials, e.g. copper, zinc, etc.

Supporting timber cladding / weatherboarding and ply.

Image showing NV6 rainscreen cladding system.
Image showing NV6 rainscreen cladding system.
Image showing NV6 rainscreen cladding system.
Blank hover image to change system image.
Blank hover image to change system image.
Blank hover image to change system image.

Features

NV6 is the NVELOPE system for supporting a timber batten – vertical cladding applications (to support vertical and/or horizontal cladding elements).

Timber batten can be used to support timber cladding/weatherboarding and ply (used as a substrate for other materials e.g metal).

Concealed fix system, utilising NVELOPE brackets plus NVELOPE carrier.

NVELOPE flexible point brackets absorb wind loading and allow for expansion and contraction.

NVELOPE fixed point brackets absorb both vertical dead loads.

NVELOPE bracket spacing is determined by cladding options such as the dimensions and weight of the facade cladding, local wind loads.

 

Support

Vertical timber cladding: vertical timber bearers are supported with NVELOPE carriers brackets fixed back to NVELOPE support brackets.

Horizontal timber cladding: vertical timber bearers are supported with NVELOPE carriers fixed back to NVELOPE support brackets, then counter battened.

More about NV6

Material:
Manufactured from extruded aluminium alloys conforming to EN 573-3 (material) and EN 755 production standards.

Options:
NVELOPE brackets (V): allows adjustment between the face of the primary support to outer face of vertical profile. Thermal isolators: hard PVC isolator assembled as standard (located between the NVELOPE bracket and the primary structural support system).

Technical Specifications:
Download NV6 technical spec here

NV6

NV6 = NV1 + NV5 Components (mechanical concealed fix)

Select NV1 components (brackets) - then - select NV6 components

Component

Reference / Carrier code

Detail

 

NV6 50 wide single

UC50S

For a 50 x 38 timber batten

NV6 50 wide double

UC50D

For a 50 x 38 timber batten

NV6 100 wide single

UC100S

For a 100 x 38 timber batten

NV6 100 wide double

UC100D

For a 100 x 38 timber batten

Fixings

SR2 4.2 x 16

4.2-16

NV6 carrier to bracket

Timber fixing screws

4.8T-25

Batten to NV6 carrier

Image showing NV6 rainscreen cladding system.

Range of Adjustment (Single / Double - 6.5mm / 11mm)

Size (mm)

Min (mm)

Max (mm)

NVELOPE 60

105

145

NVELOPE 90

135

175

NVELOPE 120

165

205

NVELOPE 150

195

235

NVELOPE 180

225

265

NVELOPE 210

255

295

NVELOPE 240

285

325

NVELOPE 270

315

355

NVELOPE 300

345

385

6.5mm holes (suitable for steel and / or timber substrates) / 11mm holes (suitable for block / concrete substrates)
NVELOPE isolators: Included as standard - if isolator not required reduce dimensions by 5mm
For use only in the vertical plane - use counter battens for vertical cladding.